Resultados: 2
#1
au:"Vaz, P."
Filtros
Ordenar por
Página
de 1
Próxima
1.
Relationship between Zoometric Measurements in Holstein-Friesian Cow and Cubicle Size in Dairy Farms
Facebook Twitter
Facebook Twitter
- Outras redes sociais
- Google+
- StambleUpon
- CiteULike
- Mendeley
- Outras redes
- Métricas
Cerqueira, J. O. L
; Araújo, J. P. P
; Vaz, P. S
; Cantalapiedra, J
; Blanco-Penedo, I
; Niza-Ribeiro, J. J. R
.
Body measurements in Portuguese Holstein-Friesian breed and its association with the dimensions of the cubicles were investigated. During a period of 5 months, body measurements and cubicles size data from 55 commercial Portuguese dairy herds were collected including in total 1054 individual cows. Data were analyzed using the general linear model and principal components. The most relevant body measurements were: height at withers (141.1±4.72 cm), height at rump (144.2±4.47 cm), length of trunk (170.8±8.31 cm), width of biiliac (55.9±4.17 cm) and perimeter of the thorax (206.8±10.43 cm). In general, the first class of parity showed significant different measures (P<0.001) associated with the development of animals. Head to head cubicle length and cubicle width were 223.0±11.0 cm and 113.0±5.0 cm respectively; whereas in cubicle against wall length was 227.0±18.0 cm and width 111.0±7.0 cm. The highest correlations were found for body measures between the different heights and between the height at chest and perimeter of the thorax. The analysis showed no relation between body measurements and dimensions of the cubicles. Principal component analysis of the different body measurements and cubicles dimensions expressed 51.4% of the total variability, in which the first factor represented 40.2% and the second factor 11.1%.
Fueron investigadas las medidas corporales en la raza Holstein-Friesian Portuguesa y su asociación con las dimensiones de los cubículos. Durante un período de 5 meses, se recogieron las medidas corporales y los datos de tamaño de cubículos de 55 explotaciones lecheras comerciales portuguesas incluyendo un total de 1054 animales. Los datos fueron analizados utilizando el modelo linear general y componentes principales. Las medidas del cuerpo más relevantes fueron: altura a la cruz (141,1±4,7 cm), altura a la grupa (144,2±4,5 cm), longitud del tronco (170,8±8,3 cm), ancho biisquiática (55,9±4,2 cm) y el perímetro del tórax (206,8±10,4 cm). En general, la primera paridad reveló diferencias (P<0,001), lo que se encuentra asociado con el desarrollo de los animales. La longitud y la ancho del cubículo cabeza con cabeza fue 223±11 cm y 113±5 cm respectivamente, mientras que en el cubículo frente a la pared, la longitud fue 227±18 cm y el ancho de 111±7 cm. Las medidas del cuerpo con las más altas correlaciones se observaron entre las diferentes alturas y entre la altura del pecho y el perímetro del tórax. El análisis no evidenció relación alguna entre las medidas del cuerpo y las dimensiones de los cubículos. El análisis de componentes principales de las medidas del cuerpo y de las diferentes dimensiones de los cubículos explican el 51,4% de la variabilidad total, en la que el primer factor representa el 40,2% y el segundo el 11,1%.
8807 downloads
2.
A low-mass neutron flux monitor for the n _TOF facility at CERN
Facebook Twitter
Facebook Twitter
- Outras redes sociais
- Google+
- StambleUpon
- CiteULike
- Mendeley
- Outras redes
- Métricas
Mastinu, P. F.
; Abbondanno, U.
; Aerts, G.
; Alvarez, H.
; Andriamonje, S.
; Angelopoulos, A.
; Assimakopoulos, P.
; Bacri, C.O.
; Badurek, G.
; Baumann, P.
; Becvár, F.
; Beer, H.
; Benlliure, J.
; Berthier, B.
; Berthomieux, E.
; Boffi, S.
; Borcea, C.
; Boscolo-Marchi, E.
; Bustreo, N.
; Calviño, P.
; Cano-Ott, D.
; Capote, R.
; Carlson, P.
; Cennini, P.
; Chepel, V.
; Chiaveri, E.
; Coceva, C.
; Colonna, N.
; Cortes, G.
; Cortina, D.
; Couture, A.
; Cox, J.
; Dababneh, S.
; Dahlfors, M.
; David, S.
; Dolfini, R.
; Domingo-Pardo, C.
; Duran, I.
; Eleftheriadis, C.
; Embid-Segura, M.
; Ferrant, L.
; Ferrari, A.
; Ferreira-Lourenco, L.
; Ferreira-Marques, R.
; Frais-Koelbl, H.
; Furman, W.I.
; Giomataris, Y.
; Goncalves, I.F.
; Gonzalez-Romero, E.
; Goverdovski, A.
; Gramegna, F.
; Griesmayer, E.
; Gunsing, F.
; Haight, R.
; Heil, M.
; Herrera-Martinez, A.
; Ioannides, K.G.
; Janeva, N.
; Jericha, E.
; Käppeler, F.
; Kadi, Y.
; Karamanis, D.
; Kelic, A.
; Ketlerov, V.
; Kitis, G.
; Koehler, P.E.
; Konovalov, V.
; Kossionides, E.
; Lacoste, V.
; Leeb, H.
; Lindote, A.
; Lopes, M.I.
; Loriggiola, M.
; Lozano, M.
; Lukic, S.
; Markov, S.
; Marigo, S.
; Marrone, S.
; Martinez-Val, J.
; Mengoni, A.
; Milazzo, P.M.
; Minguez, E.
; Molina-Coballes, A.
; Moreau, C.
; Neves, F.
; Oberhummer, H.
; O'Brien, S.
; Pancin, J.
; Papaevangelou, T.
; Paradela, C.
; Pavlik, A.
; Pavlopoulos, P.
; Perez-Parra, A.
; Perlado, J.M.
; Perrot, L.
; Peskov, V.
; Plag, R.
; Plompen, A.
; Plukis, A.
; Poch, A.
; Policarpo, A.
; Pretel, C.
; Quesada, J.M.
; Radici, M.
; Raman, S.
; Rapp, W.
; Rauscher, T.
; Reifarth, R.
; Rejmund, F.
; Rosetti, M.
; Rubbia, C.
; Rudolf, G.
; Rullhusen, P.
; Salgado, J.
; Savvidis, E.
; Soares, J.C.
; Stephan, C.
; Tagliente, G.
; Tain, J.L.
; Tapia, C.
; Tassan-Got, L.
; Tavora, L.M.N.
; Terlizzi, R.
; Terrani, M.
; Tsangas, N.
; Vannini, G.
; Vaz, P.
; Ventura, A.
; Villamarin-Fernandez, D.
; Vincente-Vincente, M.
; Vlachoudis, V.
; Vlastou, R.
; Voss, F.
; Wendler, H.
; Wiescher, M.
; Wisshak, K.
; Zanini, L.
.
A small-mass system has been developed for monitoring the flux of neutrons with energy up to 1 MeV at the new time-of-flight facility at CERN, n_TOF. The monitor is based on a thin Mylar foil with a 6Li deposit, placed in the neutron beam, and an array of Silicon detectors, placed outside the beam, for detecting the products of the 6Li(n, alpha)³H reaction. The small amount of material on the beam ensures a minimal perturbation of the flux and minimizes the background related to scattered neutrons. Moreover, a further reduction of the gamma-ray background has been obtained by constructing the scattering chamber hosting the device in carbon fibre. A detailed description of the flux monitor is here presented, together with the characteristics of the device, in terms of efficiency, resolution and induced background. The use of the monitor in the measurement of neutron capture cross-sections at n_TOF is discussed
1444 downloads
Exibindo
itens por página
Página
de 1
Próxima
Visualizar estatísticas de
Enviar resultado
Exportar resultados
Sem resultados
Não foram encontrados documentos para sua pesquisa
Glossário e ajuda para busca
Você pode enriquecer sua busca de uma forma muito simples. Use os índices de pesquisa combinados com os conectores (AND ou OR) e especifique cada vez mais sua busca.
Por exemplo, se você deseja buscar artigos sobre
casos de dengue no Brasil em 2015, use:ti:dengue and publication_year:2015 and aff_country:Brasil
Veja abaixo a lista completa de índices de pesquisa que podem ser usados:
Cód. do Índice | Elemento |
---|---|
ti | título do artigo |
au | autor |
kw | palavras-chave do artigo |
subject | assunto (palavras do título, resumo e palavras-chave) |
ab | resumo |
ta | título abreviado da revista (ex. Cad. Saúde Pública) |
journal_title | título completo da revista (ex. Cadernos de Saúde Pública) |
la | código do idioma da publicação (ex. pt - Português, es - Espanhol) |
type | tipo do documento |
pid | identificador da publicação |
publication_year | ano de publicação do artigo |
sponsor | financiador |
aff_country | código do país de afiliação do autor |
aff_institution | instituição de afiliação do autor |
volume | volume do artigo |
issue | número do artigo |
elocation | elocation |
doi | número DOI |
issn | ISSN da revista |
in | código da coleção SciELO (ex. scl - Brasil, col - Colômbia) |
use_license | código da licença de uso do artigo |